Pocket/bag filters

Manufacturer · Custom & Bulk Supply

Pocket & Bag Air Filters for HVAC Systems

Primary, medium-efficiency and activated carbon pocket filters—with configurable dimensions, media, frames and pocket layouts.

Find a starting size in the catalog, check what matters for replacement, or send a drawing for a custom requirement. The listed sizes do not limit the scope of custom production.

synthetic pocket bag filters f7 f8

What is a pocket air filter?

A pocket air filter, also called a bag air filter in HVAC applications, uses multiple media pockets attached to a frame. Primary and medium filters address particulate requirements; carbon-media pocket filters address defined odor or gas-phase requirements and need a separate application assessment.

Product Range

Choose the Filtration Task First

Start with the particulate or odor-control requirement, then compare size and construction. These product families are not simply three steps on one efficiency scale.

paint booth pocket bag air filter

Primary Pocket Filters

For the coarse-particle prefiltration stage in HVAC and air handling systems.

Literature grades

G3 / G4

Frames

Aluminum alloy / galvanized steel / Custom

Pocket configurations

500 / 600 mm; 5 / 6 / 8 pockets

pocket filter premium black background chuqi

Medium-Efficiency Bag Filters

Nonwoven pocket filters for finer particulate-filtration requirements.

Literature grades

F5 / F6 / F7 / F8 / F9

Media

Composite nonwoven

Frames

Aluminum alloy / galvanized steel / Custom

Activated Carbon Pocket Air Filter with Galvanized/Aluminum Frame

Activated Carbon Pocket Filters

For defined odor-control requirements, selected against the target contaminants.

Function

Odor / gas-phase requirements

Selection inputs

Contaminant, airflow and environment

Particle filtration

Specify separately when required

Catalog Reference

Dimensions, Pocket Counts & Listed Airflow

Use these references from the primary and nonwoven medium-filter sheets to identify a starting configuration—not to assume equivalent performance between product families.

500 mm catalog depth references. Airflow values are catalog references, not results measured at one common pressure drop.
Catalog dimensions (mm)PocketsPrimary range Airflow (m³/h)Medium range Airflow (m³/h)
495 × 295 × 50051,5001,000
495 × 495 × 50052,5001,800
595 × 295 × 50062,0001,300
595 × 495 × 50063,2002,200
595 × 595 × 50083,8002,600

600 mm catalog depth references. Airflow values are catalog references, not results measured at one common pressure drop.

Catalog dimensions (mm)PocketsPrimary range
Airflow (m³/h)
Medium range
Airflow (m³/h)
495 × 295 × 60051,8001,200
495 × 495 × 60053,2002,200
595 × 295 × 60062,5001,600
595 × 495 × 60064,0002,700
595 × 595 × 60084,5003,200

Transcribed from the Primary Pocket Filter and Nonwoven Pocket Filter product sheets. Frame/header depth is not separately specified in these dimension entries. Confirm the selected grade, media, frame details and operating conditions in the final specification.

Same dimensions ≠
same operating
performance

Primary: 3,200 m³/h Medium: 2,200 m³/h
Both sheets list 595 × 495 × 500 mm with 6 pockets, but with different catalog airflow. A matching outside size is not enough to approve a change from primary to medium filtration; check performance at the actual required airflow.

Your required size is not listed?

Automated multi-layer meltblown composite media roll equipment for pocket filter media roll wholesale manufacturing
bag air filter pockets in carton
Heavy-duty cartoon packaging for bulk nonwoven bag filter wholesale shipment to international HVAC clients

Factory & Custom Production

Manufacturing Beyond Standard Catalog Sizes

The catalog shows reference configurations, not the limit of what we manufacture. For an unlisted size or a different construction, define the installation and filtration requirements together.

Dimensions & Pockets

Frame width, height and depth; pocket depth, count and layout. Include the mounting details and space behind the frame.

Media & Frames

Specify the media requirement and frame material. Primary and nonwoven literature lists aluminum-alloy and galvanized-steel frame options.

Labels & Packaging

Include product codes, label content, artwork and packing instructions in the quotation request. Confirm private-label scope with the order.

Repeat-Order Specifications

Identify the configuration and revision used for the quotation so future orders refer to the same agreed requirements.

Can’t find your configuration? Send dimensions, quantity and any available label, photographs or drawing. Mark missing details as unknown.

Activated Carbon Pocket Filters

Add Odor Control to a Pocket Filter Configuration

Our activated carbon bag filters use a synthetic nonwoven composite containing bonded activated carbon. The nonwoven structure provides particulate filtration, while the carbon adsorbs suitable gaseous contaminants. These are two different functions: a particulate grade alone does not describe odor-removal performance.

Replacing a standard bag filter?
Match the frame, gasket and available pocket depth first. Then confirm both the particulate-filtration requirement and the odor-control objective. The same dimensions do not make a carbon pocket filter an equivalent replacement.

Comparing carbon filter quotations?
Do not compare pocket count or outside dimensions alone. Ask which carbon media is used, how much is incorporated in the proposed filter, and what gas-removal data are available at the required airflow.

Three Checks Before You Order

01

Identify the gas, not just the smell

Different contaminants can require different adsorbent media. Do not assume a general-purpose carbon configuration is suitable for ammonia, acid gases and solvent vapors alike.

02

Check performance at your airflow

A removal claim is only useful when the target gas, inlet concentration, airflow and test conditions are stated. Ask what the available data actually cover before using a percentage or service-life claim to compare products.

03

Do not use pressure drop as a carbon-life gauge

Pressure drop helps track airflow resistance; it does not by itself show how much adsorption capacity remains. Define a replacement criterion appropriate to the target contaminant and treatment objective.

For hazardous gases or a specified outlet limit, suitability must be supported by application-specific performance evidence—not by an odor-control description alone.

Have an existing carbon filter to replace?

Send its label, dimensions and photos, together with the odor source or target gas. If the contaminant is unknown, describe where the odor comes from instead of guessing.

Custom Order Process

From Your Filter or Drawing to a Confirmed Specification

Identify missing requirements before production approval. Start with the information available rather than guessing specifications.

01

Send the Starting Information

Provide dimensions, quantity and filter type. Attach replacement photos and labels, or a drawing and project specification.

02

Define the Configuration

Confirm frame, media, pocket depth/count and sealing. Add airflow and required test standard; identify carbon application details separately.

03

Confirm the Quotation Scope

Identify the exact configuration, labels and packing. State required samples, documents or tests so their availability and scope can be confirmed.

04

Approve the Specification / Agreed Sample

Confirm the specification revision and what any agreed sample verifies. Fit or appearance approval is not proof of an untested performance rating.

05

Confirm Bulk Supply Details

Agree on quantity, applicable checks, identification, packing and delivery requirements. Record configuration changes and retain the approved revision for repeat orders.

No Complete Drawing? Start with Photos.

  • Complete-filter and clear-label photographs.
  • Frame and gasket detail.
  • Measured dimensions and required quantity.
  • Destination and known operating requirements.

Copy a general inquiry template

Project: new / replacement / custom bulk order
Filter type: primary / medium / carbon / unknown
Frame W × H × thickness: [ ] mm
Pocket depth / count: [ ]
Media, grade and required standard: [ ]
Airflow per filter: [ ] m³/h or unknown
Frame material / gasket: [ ]
Quantity by size / destination: [ ]
Labels, packing or sample requirements: [ ]

Specifications, Replacements & Custom Orders

Pocket & Bag Air Filter FAQs

Answers to common questions about filter terminology, replacement specifications, performance documents and custom configurations.

A: In HVAC air filtration, pocket filters and bag filters commonly refer to the same multi-pocket air-filter format. This page covers filters installed in ventilation and air handling systems—not liquid filter bags or baghouse dust-collector bags.

When requesting a quotation, include a product photo or application description so the required filter type is clear.

A: The label is a useful starting point, but it may not identify the frame/header thickness, gasket location or complete performance specification.

Include measured frame width and height, frame thickness, pocket depth, pocket count and sealing details. If measured dimensions differ from the label, provide both instead of rounding to the nearest catalog size.

A: No. A grade conversion is not a product test result. The G3/G4 and F5–F8 designations shown on this page follow the supplied product literature.

If your project requires ISO 16890 or ASHRAE 52.2 / MERV, state that requirement in the inquiry and confirm which supporting document is available for the proposed configuration. Do not assume a report for one model covers every size, media or pocket arrangement.

A: Yes. The catalog shows representative configurations, not the complete limit of custom production.

Send the required frame dimensions and material, pocket depth and count, gasket arrangement, filtration requirement and quantity. Include available installation space when changing pocket depth or layout. These details need to be considered together before confirming the configuration.

A: Do not assume washability from the pocket shape or a general reusable claim. A cleaning method and continued performance would need to be established for the exact media and construction.

There is no single replacement interval for every application. Use the selected filter’s agreed operating limits, equipment maintenance requirements and site conditions. For carbon media, pressure drop alone does not indicate remaining adsorption capacity.

A:  Start with filter type, dimensions, quantity and destination. Add the required grade and standard, airflow if known, and available labels, drawings or photos. Mark missing information as unknown.

State whether you need a sample to check fit or construction, a datasheet, or a specific performance document. Sample availability, document scope, minimum quantities, packaging and lead times must be confirmed for the proposed order.

Need Tech Datasheets or Samples? Let’s Connect.

Get professional air filtration product support and solutions from our expert team.

Get In Touch

Address

Hanjia industrial area, Huangshan street, Zouping, Shandong, China 256200

Room 1304, Block A, China Europe International Building, NO.7 Jinjie, Mashang Street Office, Zhangdian District, Zibo, Shandong, China 255000

Email

Whatsapp

Phone

+86 13506981008

Follow Us

Scroll to Top